RV Water Heater Reset Button: Where It Is and How to Reset

TL;DR

  • Many RV water heaters have no single reset button. If a red RESET or lockout light comes on after the burner fails to light, switch the heater OFF, then ON. Suburban says to wait 5 seconds in between.
  • An overheat (ECO) trip is a different reset. On Suburban DSI heaters it is a push button under a rubber grommet (gas/electric models have two), and the water must be below 110°F first. On Dometic WH heaters it is the switch only: let the water cool, switch OFF for 30 seconds, then ON.
  • Find the cause before you reset a second time. If you smell gas, see soot, or the lockout comes back, stop and call a technician.

If you are looking for the RV water heater reset button because the hot water quit, you may not find a single button. Depending on the brand, “reset” means a switch cycle, an overheat push button, or both. Two parts people often blame, a fuse and a thermal cut-off, are replaced, never reset.

This guide follows three manufacturer manuals: the Suburban water heater manual (PN 205269) for its DSI models, the Dometic WH-series manual (form 3317866), and the Dometic (Atwood) 4, 6 and 10 gallon manual (MPD 93756). The label on your heater tells you which one applies.

Three terms come up a lot. DSI means direct spark ignition: the heater lights itself with a spark and has no pilot flame. Lockout means the heater has stopped trying to light. ECO means energy cut-off, a high-temperature limit switch that shuts the heater down if the water gets too hot. This is propane and 120V equipment, so safety comes before speed.

Affiliate disclosure: This page may contain affiliate links. If you buy through these links, we may earn a small commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.

RV Water Heater Reset Button: How Do I Reset It?

Switch the heater OFF at its control switch, wait, then switch it back ON. Suburban says to wait 5 seconds after an ignition lockout. Dometic and Atwood say 30 seconds after an overheat lockout. If the heater shut down because the water got too hot, let it cool and find out why before you reset it.

Safety

  1. If you smell gas, do not reset anything. The Suburban and Dometic manuals give the same steps: get everyone out, shut off the gas at the container or source, do not touch electrical switches, phones or radios, and do not start the engine or generator. Call a gas supplier or qualified technician, or the fire department if you cannot reach one. Leave the gas off until the leak is repaired.

Before you reset, check the basics:

  • The LP supply is on and the tank is not empty.
  • 12V power is present, and the water heater’s 120V breaker is on if you use electric mode. If you are unsure which control operates the heating element, see our RV water heater electric switch guide—the element switch and ignition reset are not the same control.
  • The tank is full and the air is out. Suburban says to refill the heater and remove all air from the tank and lines before relighting or turning the power back on.
Ignition Lockout: Red Light After the Burner Fails to Light
  1. Suburban DSI models The heater tries to light up to three times, with a 15 second purge before each try. If the red RESET light is still on after the third try, the heater is in lockout. Switch OFF, wait 5 seconds, then switch ON.
  2. Dometic WH-series After three failed tries the red lockout lamp comes on. Dometic says to turn the switch OFF, then ON. If the switch light stays on longer than 15 seconds, switch OFF, wait 5 minutes, and try again.
  3. Atwood 4, 6 and 10 gallon, electronic ignition If the remote switch light stays on longer than 15 seconds, switch OFF and wait 5 minutes before you try again.
Overheat (ECO) Lockout: Heater Shut Down on High Water Temperature
  1. Dometic WH-series Find and correct what caused the overheating. Let the water cool. Then switch OFF, wait 30 seconds, and switch ON.
  2. Atwood 4, 6 and 10 gallon, electronic ignition After the water cools, leave the switch OFF for at least 30 seconds, then turn it ON.
  3. Atwood gas/electric models in electric mode If the manual reset high temperature limit switch trips, press the reset switch with a pencil or other nonmetallic object. If it trips again, contact a Dometic service center.
  4. Suburban DSI models Wait until the water is below 110°F. On gas/electric models, switch the electric element OFF before you push grommet B, as a precaution. Then push the rubber grommet to press the reset button under it. The location table below shows which button is which.

Two more points from the manuals. Suburban DSI heaters have no pilot, so never try to light the burner by hand. And if a lockout keeps coming back, the Dometic and Atwood manuals both say to contact a Dometic service center. A reset is not a repair.

Lockout, ECO Trip, Fuse or Thermal Cut-Off: Which Is It?

Use this table to match what you see to what the manuals describe. The first two rows are things an owner can reset. The last two are parts that get replaced, and the manuals treat that as service work.

What You See and What the Manuals Say
What you seeWhat it likely meansWhat the manual says
Red RESET or lockout light after the burner fails to light Ignition lockout Check the gas supply first. Then switch OFF and back ON. Suburban says to wait 5 seconds.
Heater shut down after the water got too hot, or electric mode stopped heating Overheat (ECO or high temperature limit) trip. If the tank was run dry, the element may be burned out. Let the water cool. Suburban: push the grommet button once the water is below 110°F. Dometic WH and Atwood electronic ignition: switch OFF for 30 seconds, then ON. Atwood gas/electric in electric mode: press the reset switch with a pencil.
No light and no response at all Possibly a blown fuse on the DSI control board (Dometic WH and Atwood) The fuse is a 2 amp mini ATO style. Never fit one larger than 3 amps. Dometic says to check for a short outside the board first.
Still dead with a good fuse A voltage problem, or a melted thermal cut-off (Dometic WH and Atwood) Both manuals flag supply voltage above 14 volts. A thermal cut-off melted by a flue obstruction must be replaced after the obstruction is removed. It cannot be reset.

The Dometic WH manual adds one more electrical check for a dead unit: less than 10 volts DC on the thermostat line. Both Dometic manuals say installation and service belong to a qualified technician or service center, so treat the fuse, voltage and thermal cut-off rows as things to tell your technician about, not weekend projects.

Some home water heater guides say to hold the reset button for about 30 seconds. That advice is written for household tank heaters. None of the three RV manuals used here describes holding a button. They describe a switch cycle, or a single press on a Suburban grommet or the Atwood reset switch.

Where Is the Reset Button on My RV Water Heater?

It depends on the brand. Suburban DSI heaters have a reset button under rubber grommet A, behind a cover marked PUSH TO RESET, and gas/electric models add a second one under grommet B. Atwood combination gas and electric heaters have a high temperature limit reset switch you press with a pencil. The Dometic WH manual describes no pressed button at all, only the OFF and ON switch cycle.

Reset Location by Heater Family
Heater familyWhere the reset isWhat to know
Suburban gas-only DSI models (the “D” models, SW4D to SW16D) One button behind the PUSH TO RESET cover, under rubber grommet A (12V gas side). The button trips when the water goes above 180°F. It will only reset once the water is below 110°F.
Suburban gas/electric DSI models (DE, DEM, DEC and DELC) Two buttons behind the PUSH TO RESET cover, each under a rubber grommet. A is the 12V gas side. B is the 120V electric element. Same 180°F trip and 110°F reset rule. As a precaution, switch the electric element OFF before you push B.
Dometic (Atwood) 4, 6 and 10 gallon combination gas and electric A manual reset high temperature limit switch, shown in the manual’s drawing of the combination unit. Press it with a pencil or another nonmetallic object. The manual puts the electric power switch at the rear of the heater and asks for clearance there. If problems continue, contact a Dometic service center.
Dometic WH-6GA, WH-6GEA, WH-9GEA, WH-10GEA, WH-16GEA No pressed button is described. The reset is the control switch: OFF, then ON. The manual says to let the water cool but gives no cool-down temperature. Do not borrow Suburban’s 110°F or its button layout.
Atwood pilot models with a Robertshaw control A “reset” push button on the gas control This button is held while lighting the pilot. It is a pilot-lighting control, not an overheat reset.

On Suburban heaters, the manual shows the reset buttons in the same drawing as the electric element’s ON/OFF switch. That switch sits in the lower left corner of the control housing, behind the water heater door, so start looking there.

Whatever the brand, read the label on the heater first and match it to the maker’s manual. Do not press an unlabeled button without it.

Why Does My Water Heater Keep Tripping or Locking Out?

A reset that does not hold is telling you something. Dometic’s manual is direct about it: investigate and correct the overheating before you reset. Work through these causes in order, from simple to serious.

  1. No gas. An empty LP tank or a closed valve will cause three failed light attempts and a lockout every time.
  2. No water in the tank. Suburban says the tank must be full before the electric element is switched on, and calls powering up an unfilled heater the most common problem it sees with electric water heaters. The Atwood manual adds that turning on power without water over the element may burn it out and void the warranty. If you recently finished draining the water heater or pulled the anode rod, refill the tank and purge the air first.
  3. Thermostat or ECO trouble. Dometic says a failed thermostat makes the ECO open and lock the system out, and that the thermostat must make good contact with the tank. On Suburban heaters the ECO trips above 180°F. A heater that overheats again after one reset needs a technician.
  4. Power problems. A blown 2 amp fuse or supply voltage above 14 volts can leave a Dometic or Atwood heater dead.
  5. A blocked burner or flue. Dometic says spiders, mud wasps and other insects can nest in the burner tube, and that a soft, lazy or very yellow flame points to an obstruction. Suburban warns that a yellow flame causes soot.

A few related warnings from the same manuals:

  • Scalding. Suburban says water above 125°F can cause severe burns almost instantly. Be careful when you test a hot faucet after a reset.
  • Hydrogen gas. Both Suburban and Dometic say hydrogen can build up when the hot water system sits unused for two weeks or more. Run a hot faucet for several minutes before using electrical appliances on the hot water system, and keep flames away from the open faucet.
  • Driving. The Dometic WH and Atwood manuals say gas appliances must never run while the vehicle is moving.
  • No add-on parts. Dometic says not to fit aftermarket heating elements, because they can lack critical safety controls.

When Should I Stop and Call a Technician?

Stop and call a qualified technician if you smell gas, see soot or a yellow flame, or the lockout returns after a reset. Stop too if a thermal cut-off has melted or a new fuse blows again. The manuals assign repairs to a qualified technician or service center, and a melted cut-off must be replaced, not reset.

Stop and get help

  1. Gas smell: follow the gas steps near the top of this page and leave the gas off until the leak is repaired.
  2. Soot: Suburban says to shut the heater down immediately and contact a dealer or qualified service person. Dometic warns that carbon monoxide has no odor and can be life-threatening.
  3. Overheating, or gas that will not shut off: the Dometic and Atwood manuals say to turn the switch OFF and turn the gas off at the LP tank.
  4. A lockout that returns, or a light that stays on after a reset.
  5. A heater that has been under water: Suburban says not to use it until a qualified technician has inspected it.

One part needs extra care: the pressure and temperature (P/T) relief valve. All three manuals say some dripping while the water heats is normal expansion. Suburban says the valve opens at 210°F or 150 psi and must never be plugged. The manuals do not describe steady discharge, but a valve that keeps flowing likely means something is wrong with temperature or pressure. Turn the heater off and ask a technician. Never tamper with the valve. Our pressure relief valve replacement guide explains when dripping needs diagnosis rather than an immediate replacement.

Why Is There No Hot Water If the Heater Isn’t Locked Out?

If no red light is on, the problem may be upstream of the heater. Check for an empty LP tank, missing 12V or 120V power, a heater left in bypass or never refilled, or no water reaching the faucets. Work through these before you press any reset.

A heater left in winter bypass may deliver cold water from the hot tap even when its controls work. See how to undo an RV water heater bypass before attempting another reset.

  • Still in bypass. Suburban says to leave the heater in bypass for winter when a bypass kit is fitted. If nobody switched it back after de-winterizing the plumbing, the tank can be empty while the faucets still run. The same applies if you bypassed it while winterizing with antifreeze.
  • No water flow. A pump or hookup problem can look like a heater problem. See our guide to an RV water pump not working, or learn how to prime the pump if it runs but moves no water.
  • Switch on, nothing happening. Gas or power may not be reaching the heater. Go back to the table above.
  • Dometic EXT models only. Dometic’s manual links low flow or cold water on EXT models to the mixing valve. That valve is not serviceable and must be replaced if it is faulty, so call a technician.

What If My Heater Has No Reset Button or Isn’t Listed Here?

Many heaters have no button to press. On those, the reset is the switch cycle described above. If your model is not one of the families in this guide, do not assume the steps carry over.

  • This guide does not cover Dometic (Atwood) XT heaters, older Suburban pilot-light models, tankless heaters or other brands. The Suburban manual used here covers DSI models only.
  • Find the brand and model number on the heater’s label, then use the maker’s own manual for that exact model.
  • Do not use forum or video tricks on gas, 120V or pressurized water parts.
  • If you cannot find a manual, stop and contact the manufacturer or a qualified technician.

For older Atwood and Dometic water heaters, see our model-specific Atwood water heater troubleshooting guide before applying reset instructions from a different heater family.

If the heater runs fine but the hot water stinks, that is a separate problem. See our guide to a rotten egg smell from the water heater.

Before You Press Anything

Know which reset you need: a lockout switch cycle, or an overheat button on some models. Reset only after the water has cooled and you know why it tripped. On Suburban heaters, cooled means below 110°F.

If you smell gas, see soot, find a melted thermal cut-off, or the lockout keeps returning, stop and call a technician.

Your next step is to find the model label on your heater and open that maker’s manual.

Written by

RV Flush Guide Editorial Team

RV Flush Guide Editorial Team creates practical, research-based guides on RV toilets, plumbing, holding tanks, sewer systems, and sanitation. We use manufacturer documentation, product manuals, and reliable technical sources to make troubleshooting and maintenance easier for RV owners.

Leave a Comment