  • Atwood water heater troubleshooting starts with gas: if you smell propane, get everyone out and shut off the gas at the tank. If not, start with the cheap checks: LP gas on, the bypass valves set for normal use, water in the tank, 12V power, and the control switch.
  • If the lockout light is on, follow your model’s reset steps once (after a high-temperature lockout, let the water cool, then switch off for 30 seconds). If it locks out again, call a service center.
  • A blown board fuse, a melted thermal cut-off, gas pressure, and a mixing valve are technician jobs. The right steps depend on your model, so check the label first.

If there is no gas smell, the next step is knowing which heater you have, because the checks differ by model family. Atwood heaters are now documented under the Dometic name, so this guide follows Dometic’s own manuals. It works in a safe order: gas smell first, easy checks next, then lockouts and the parts that need a pro.

The manuals say service must be done by a qualified technician or service center. This guide covers what owners can check and where to stop. It applies only to the models in the Dometic manuals named below. For any other brand or model, use that maker’s manual.

Affiliate disclosure: This page may contain affiliate links. If you buy through these links, we may earn a small commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.

Atwood Water Heater Troubleshooting: What Should I Do If I Smell Gas?

Treat a gas smell as an emergency: get everyone out of the RV and shut off the gas at the tank or source. Don’t touch any electrical switch or use a phone or radio inside, and don’t start the vehicle or generator. Call a gas supplier or qualified technician, or the fire department if you can’t reach one. Leave the gas off until the leak is repaired.

Don’t use matches, candles, or any flame to look for a leak. Dometic’s manual for the WH series also warns that a gas-burning heater can produce carbon monoxide, which you can’t smell. Dometic’s manuals also say the gas should be off at the tank whenever the vehicle is moving.

Which Atwood or Dometic Water Heater Do I Have, and Which Manual Applies?

Check the model number on the unit’s label, behind the access door. Older Atwood-era models like G6A, GC6AA, G10, and GC10A follow Dometic’s 4-6-10 gallon manual. Models ending in EXT follow the XT manual. Newer WH-6GA through WH-16GEA models follow Dometic’s WH-series manual. Other brands need their own manual.

Dometic Water Heater Families and Their Manuals
FamilyExample modelsWhat is differentManual
Pilot G4, G6A, GC6AA, G10 You light a pilot flame by hand or with a spark module. A “P” suffix marks pilot relight. 4-6-10 gallon manual
Electronic ignition G6A-8E, GCH6A-9E, G10-3E A 12V remote switch with a lockout light. The “E” suffix means electronic ignition. 4-6-10 gallon manual
Gas/electric combo Models with “C” (GC6AA, GC10A) Adds a 120V element and a manual-reset high-limit switch. 4-6-10 gallon manual
XT Models ending in EXT Has a mixing valve on the outlet. XT manual
WH-series WH-6GA, WH-6GEA, WH-9GEA, WH-10GEA, WH-16GEA The 6GA is gas only. The “GEA” models add an electric element. WH-series manual

Models with “H” (engine heat exchange), such as GH6 or GCH10A, also fall under the 4-6-10 manual.

Dometic’s 4-6-10 gallon manual is available from Dometic’s support page for the G10 heater. It says older revision numbers (3, 4, 6, 7, 8, and 9) are generally covered. The WH-series manual says its instructions are generally applicable regardless of revision.

If your model isn’t listed in these manuals, whether a procedure applies is unconfirmed. Contact Dometic or a Dometic service center, or the maker of your heater. Dometic’s parts and service-center lookup is at dometic.com.

What Is the Safe Order of Checks When There Is No Hot Water?

Work from the simplest check to the most serious. Confirm there is no gas smell, LP is on, the bypass valves are set for normal use, the water system is on and the tank is full, and the heater switch is on with 12V power present. Check for a lockout light. If all of that is fine and the heater still won’t run, use the symptom table below to see which causes you can check and which need a technician.

If your RV was recently winterized, check that the heater is no longer isolated. Our guide to restoring the RV water heater bypass valves explains how to return the plumbing to normal use before continuing with no-heat checks.

No Hot Water: Check in This Order
  1. Rule out gas first If you smell gas, don’t operate the heater. Go back to the gas-smell steps above.
  2. Turn on LP and water Dometic’s manual says the LP and water systems must both be on.
  3. Check the bypass valves If the heater was bypassed for winterizing, water skips the tank and the faucets run cold. Set the valves back to normal flow. Valve layouts vary by RV, so follow your RV’s plumbing diagram.
  4. Make sure the tank is full Never run the heater, or its electric element, with an empty tank. Dometic says the element can burn out if it runs dry.
  5. Vent the hot lines if the RV sat unused After more than two weeks, hydrogen gas can form in the hot water system. Open the kitchen hot faucet for several minutes before using any electrical appliance on the hot water system, and keep flames and smoking away from the open faucet.
  6. Check the switch and the 12V supply Dometic says not to power the heater from a battery charger, even for testing.
  7. Look at the lockout light The next section explains what it means.
  8. Clear the vent and combustion air grille Both must be free of debris and nests.
  9. Check the temperature setting on pilot models Dometic recommends the mid-point between warm and hot.
  10. Confirm water reaches the faucets If the faucets give no water at all, the problem is upstream of the heater. Start with the RV water pump not working guide. Then prime the pump. If you just took the RV out of storage, follow the steps for de-winterizing RV plumbing.

On 4-6-10 pilot models, follow the full lighting steps in that manual: wait 5 minutes before relighting, hold the control for 30 seconds, and repeat with a longer hold if the pilot won’t stay lit. If you smell gas at any point, stop and follow the gas-smell steps above. Don’t tamper with the pilot orifice.

Why Is My Water Heater Locked Out and the Red Light On?

A lockout means the heater shut itself down on purpose, so reset it once and call a service center if it comes back. On the WH series, the heater makes three ignition tries, then locks out and lights the red lamp. A high-water-temperature lockout also lights it. Let the water cool, switch the heater off for at least 30 seconds, then back on. If it locks out again, don’t keep resetting. Call a Dometic service center.

What to do depends on your model family:

  • 4-6-10 electronic ignition models: If the remote switch light stays on for more than 15 seconds, turn the switch off, wait 5 minutes, and try again. After a high-temperature lockout (light on), let the water cool, then hold the switch off for 30 seconds before turning it on. If it persists, contact a Dometic service center.
  • WH-series models: The same 15-second rule applies. To reset a gas lockout, switch off, then on. After a high-temperature lockout, let the water cool, switch off for at least 30 seconds, then on. If the lockout persists, contact a Dometic service center.
  • Gas and electric running together (WH-series): If the gas side fails to light, it locks out, but the lamp may stay dark because the electric side still works. If recovery is slow, gas isn’t working. Turning the electric switch off lets the lamp show the gas lockout.
  • 4-6-10 combo models only: The 4-6-10 manual shows a manual-reset high-limit switch on these models (FIG 11-A in the manual). Dometic says to press it with a pencil or another nonmetallic object. If problems continue, call a Dometic service center. Don’t assume this switch exists on other models.
  • XT models: Follow the lockout steps in the XT manual for your exact model.

Stop and get help

  1. A lockout that comes back after one reset means something is wrong. Repeated resets are not a fix.

This section covers Atwood and Dometic lockouts by model family. For where reset buttons sit across brands, see the RV water heater reset button guide.

What Causes No Heat or No Ignition, and Who Should Fix It?

Dometic’s troubleshooting steps check power, the board fuse, the thermal cut-off, and the burner, in that order. Some are owner checks, but several are technician jobs because they involve gas or 120V. The table sorts each symptom by who should handle it, using Dometic’s manuals.

Symptom, Likely Cause, and Who Fixes It
SymptomLikely causeWho fixes it
Heater dead, no light, no ignition attempt Blown 2 amp mini ATO fuse on the circuit board. Dometic says to check for a short outside the board first and never use a fuse over 3 amps. Technician
Fuse is good but the heater is still dead Supply voltage over 14V. The WH manual also says to check for below 10 VDC on the thermostat line. Technician, or an experienced owner with a meter who only reads the voltage
Dead after a flue obstruction, or after running gas while driving Thermal cut-off melted. The obstruction must be removed and the cut-off replaced. Technician
Slow or late lighting, soft yellow flame Insect nest in the burner tube. Dometic describes cleaning with a wire brush and vacuum. Owner only if comfortable, with the gas off at the tank and the burner cool. Otherwise a technician. The WH manual says to call a service center if a nest can’t be removed easily.
Erratic lighting, cracked electrode porcelain, wrong electrode gap Dometic specifies a 1/8 inch electrode gap. Technician
Weak or inconsistent flame, gas pressure suspected Dometic says gas pressure should be 11 inches water column with three appliances running. Technician tests it. No adjustment steps here.
Pilot won’t stay lit (pilot models) Repeat lighting with a longer hold. If the pilot flame is low and clean, the orifice needs replacing. Owner relights. Technician replaces the orifice.
Electric mode dead (combo and WH “GEA” models) Electric switch off, or the tank is not full. Owner checks the switch and that the tank is full. On 4-6-10 combo models, see the high-limit switch in the lockout section. If electric mode still won’t run, the element, thermostat, and wiring carry 120V: technician.
Low flow or cold water (EXT models) Dometic says mixing valve corrosion or debris. Technician

Safety

  1. The element, wiring, and junction cover carry 120V. If a check points there, stop and call a technician.

Why Is My Relief Valve Dripping, and Is It Broken?

Dometic’s manuals say a dripping pressure-temperature relief valve while the heater runs does not mean the valve is defective. Heated water expands in a closed RV system, and the tank’s built-in air gap can get used up. You restore the gap with the heater off and the water cool. If a technician suspects a faulty valve, our RV water heater pressure relief valve replacement guide explains the checks and replacement requirements.

Safety

  1. Hot water from the relief valve can scald. Keep the water cool and your body clear of the outlet.
Restore the Air Gap in Order
  1. Turn the heater off The water must be cool.
  2. Turn off the pump or hookup water
  3. Open the hot faucet nearest the heater
  4. Pull the valve lever Pull it straight out and hold it until water stops flowing.
  5. Let the valve snap shut Then close the faucet and turn the water back on.
  6. Turn the heater back on Watch the valve for dripping.

Dometic says to work the valve at least once a year. If it discharges again, repeat the steps. For a permanent fix, the manuals suggest an expansion tank (diaphragm type, about 15 oz) or a pressure relief valve in the cold inlet set to 100 to 125 psi with a drain line outside. Both are plumbing jobs.

Never plug, cap, or tamper with the valve. The valve isn’t serviceable, so a faulty one must be replaced. The WH manual adds that water quality can shorten valve life and that corrosion damage isn’t covered by warranty. If you can’t tell whether the drip is expansion or a faulty valve, have a service center look. You may need to cool and drain the heater first, so see how to drain an RV water heater.

When Should I Stop and Call a Technician?

Stop and call a technician or a Dometic service center for:

  • Any gas smell.
  • Water that comes out too hot, or hot water or steam forcing its way out of the relief valve.
  • A lockout that returns after one reset.
  • A blown board fuse (a short outside the board).
  • A melted thermal cut-off.
  • Nests or debris that won’t come out easily.
  • A yellow, soft flame.
  • Any question about gas pressure.
  • Low or cold flow on a model with a mixing valve.
  • Anything under the 120V junction cover.
  • Any relief valve replacement or mixing valve work.

The manuals state that installation and service must be done by a qualified technician, service center, or gas supplier. Find a Dometic service center at dometic.com.

Never fit aftermarket heating elements. Dometic’s 4-6-10 manual warns they can cause an explosion, and the WH manual says not to use them. The WH manual also warns against bug screens, anode rods, and other non-approved devices.

When you call, have these ready: the model number, how the lockout behaves, and what you already checked.

Quick Recap: What to Check First

Start with gas. If you smell it, stop everything. If not, run the cheap checks: LP on, bypass valves set for normal use, a full tank, 12V power, the switch, and a clear vent. Reset a lockout once, and don’t keep resetting it.

Your model family decides what applies, so match your label to the right manual. A blown board fuse, a melted thermal cut-off, gas pressure, and a mixing valve are technician jobs.

After that, keep the tank clean by draining it on your manual’s schedule.

Frequently Asked Questions

Can I Run an Atwood Water Heater on Electric Only?

Only gas/electric combo models and models with an electric element can. These are the “C” models in the 4-6-10 manual and the “GEA” models in the WH series. The tank must be full first, because running the element dry can burn it out. On 4-6-10 combos, the electric thermostat is set at 140°F. For switch and wiring details, see electric switch.

Why Does My Hot Water Smell Like Rotten Eggs?

Dometic says the smell is hydrogen sulfide. For the 4-6-10 models, the manual gives a vinegar flush of 4 parts white vinegar to 2 parts water, run through the heater 4 to 5 times. Flush instructions differ by manual, so follow the one for your model. For the full process, see rotten egg smell.

Can I Put an Anode Rod or a Heating Rod in My Dometic Heater?

Not on WH-series heaters: Dometic’s WH manual warns against anode rods and aftermarket heating elements. The 4-6-10 manual says aftermarket elements can cause an explosion. For anode rods on any other model, check that model’s manual or ask Dometic.

Why Did My Heater Shut Down After I Drove With the Propane On?

Dometic says gas appliances must never run while the vehicle is moving, and the gas should be off at the tank. Wind can cause flame reversal in the burner tube and trip the thermal cut-off. A tripped cut-off must be replaced.

How Often Should I Drain My 4-6-10 Water Heater?

Dometic’s 4-6-10 manual says to drain it at least once a year and before freezing. Turn the heater off and let the water cool first, because hot water can scald. For the steps, see draining your water heater.