Shurflo Accumulator Tank: Do You Need One and How to Set It Up

TL;DR

  • An accumulator is a small pre-pressurized tank on the pump outlet that smooths pulsing and reduces on-off cycling. Shurflo’s 4008 manual says a by-pass pump needs none.
  • Shurflo’s 182 manual describes the tank for pressure-switch pumps, with the air precharge set to the pump’s turn-on pressure. Check your pump type first.
  • If the pump cycles rapidly, rule out restrictions and leaks before buying a tank.

If your pump pulses at the faucet or kicks on and off, you have probably seen forum threads arguing about whether a Shurflo accumulator tank helps. The answer depends on which pump you own. An accumulator is a small bladder tank that holds a little water under air pressure, placed on the pump’s pressurized outlet.

This page is based on Shurflo’s own manuals. It covers whether your pump needs a tank, the real specs of the 182 series, and how to check the precharge safely. Some Shurflo pump models are not documented here, so for those, your pump’s own manual is the final word. If you are chasing a cycling problem, start with the “try this before buying” checklist, then use the spec tables to compare models before spending money.

Affiliate disclosure: This page may contain affiliate links. If you buy through these links, we may earn a small commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.

What Does a Shurflo Accumulator Tank Do?

A Shurflo accumulator is a bladder tank on the pump’s pressurized outlet, with air on one side and water on the other. Shurflo says it adds a little stored water, reduces pump on-off pulsation, and helps pressure-switch pumps last longer. It is not a water storage tank and it is not a pump.

Inside, a flexible bladder separates the two sides. The air side has a valve stem, like a tire. The water side connects to your plumbing. When the pump runs, water pushes against the air cushion, and that cushion evens out the pressure.

Shurflo lists these benefits: longer pump life, less noise, less amperage draw, and less pulsation. Keep your expectations realistic, though. The tank stores only about 2 to 4 oz (60 to 120 ml) of water, so it smooths pressure but will not supply a shower.

Two terms come up often. A pressure switch is the part that turns the pump on when pressure drops and off when it reaches the shut-off pressure. The turn-on pressure is the pressure at which the switch starts the pump.

Does My Shurflo Pump Need an Accumulator?

Shurflo’s 4008 manual says no accumulator is needed with by-pass pumps. Shurflo’s 182 manual describes the tank for pressure-switch-controlled pumps and says it is not recommended for 4900 or 5900 Series Smart Sensor pumps. For any other Shurflo model, check that pump’s own manual.

A by-pass pump opens an internal valve at about 40 psi that sends water back to the pump inlet. The 4008 still has a pressure switch (it shuts off at 55 psi), so the line that matters is whether your pump has an internal by-pass, not whether it has a switch. Shurflo says the by-pass gives steady flow with virtually no cycling, which is why it does not call for an accumulator.

Which Shurflo Pump, What Does Shurflo Say?
Pump typeWhat Shurflo’s manual saysYour next step
4008 RV Revolution by-pass pump No accumulator needed Diagnose cycling before buying
Pumps without an internal by-pass (pressure-switch only) The 182 manual describes the tank and a precharge method Set precharge to your pump’s turn-on pressure
4900 or 5900 Series Smart Sensor 182 manual says not recommended Do not use a 182
Any other Shurflo model Not confirmed here Read your pump’s manual or ask Shurflo

To find your model, check the label on the pump. If you are still choosing a pump, our RV water pump guide covers the options.

What Are the Specs, and Which Shurflo Accumulator Model Should I Buy?

The 182 series is a 125 psi nylon bladder tank with 1/2-14 NPSM ports. Models are split by factory precharge: 30 psi for the 182-100 and the 182-200, and 20 psi for the 182-102 and 182-202. Match the manual to your exact model number before you buy or set anything.

Shurflo 182 Series Specs From the Manual
SpecValue
Max working pressure 125 psi
Ports 1/2-14 NPSM male
Construction Nylon housing, butyl bladder
Listings CSA and NSF listed
Temperature range 34 to 120 F
Size About 3 3/4 in diameter, 8 3/4 in long
Factory precharge 30 psi (182-100, 182-200); 20 psi (182-102, 182-202)

Volume is where listings disagree. The manual gives a total volume (gas and liquid) of 21 oz. Pentair’s product page for the 182-200 lists 24 oz. Whatever the listing says, check the precharge with a gauge before and after install. Only about 2 to 4 oz of that volume is stored water anyway.

To choose between the two precharges, pick the model whose factory setting is closest to your pump’s turn-on pressure, then fine-tune it with a gauge. Shurflo’s own example is a 45 psi pump that turns on around 30 psi, which matches the 30 psi 182-200. Retail listings sometimes label the 182-200 as a 20 psi tank, so confirm the model number and precharge on the listing before you order.

Shurflo 182 Accumulator Tank: Pick Your Precharge

182-20030 psi factory precharge
182-20220 psi factory precharge
Max working pressure125 psi
Ports1/2-14 NPSM male
Best fitPumps without an internal by-pass
Not for4900 or 5900 Smart Sensor pumps

Specs from the Shurflo 182 manual. Check the model number on the listing before you buy.

As an Amazon Associate, RV Flush Guide earns from qualifying purchases.

Skip, Add, or Go Bigger?
Your situationWhat to do
You own a 4008 and the pump cycles rapidly Skip the tank for now and diagnose first
Pump without a by-pass that pulses A 182 is a reasonable fit
4900 or 5900 Smart Sensor pump Do not use a 182
Thinking about a larger tank Shurflo also sells a 2 gallon stainless steel accumulator. It has its own documentation and is not covered here

The 181-xxx series, such as the 181-201, is a separate Shurflo manual and model family. Don’t mix its numbers with the 182’s. The 182 has no replacement parts or kits, so if one fails, you replace it.

How Do I Install a Shurflo Accumulator and Set the Precharge?

Install it on the pressurized side after the pump, before any filters or check valves, then set the air precharge to your pump’s turn-on pressure. Always check the precharge with the pump off and a faucet open, so the system holds no water pressure.

Safety

  1. This is pressurized water plumbing with an air-charged tank. Turn the pump off and isolate its power, then open a faucet to relieve pressure before touching any fitting. Never exceed 125 psi. Never put automotive antifreeze anywhere in the water system.

Stop and get help

  1. If you cannot relieve the pressure, or the pump will not shut off after you finish, stop using the pump and contact Shurflo or a qualified technician.

Have These Ready

  • A tire gauge that reads low pressures
  • A way to add or release air (a bicycle or tire pump works for adding)
  • The included fittings, hose clamps, and 1/2 in flexible line for an in-line install
  • High-pressure braided flexible tubing rated at twice the pump rating
  • Your pump’s turn-on pressure from its label or manual
Install and Precharge a Shurflo 182
  1. Know your pump’s turn-on pressure Shurflo’s example is a 45 psi pump that turns on around 30 psi, so the precharge is 30 psi. Don’t guess a number for a specific pump that the manual doesn’t give. Shurflo gives no precharge for the 4008, because it says no accumulator is needed there.
  2. Pick the mounting spot Anywhere on the pressurized side after the pump and before any filters or check valves. The ports are nondirectional, so any position works, but valve stem up is recommended for complete sanitizing and winterizing. Keep it from freezing and away from high heat.
  3. Connect and tighten it In-line: screw on the included fittings, cut the 1/2 in flex line at the pump outlet, and use hose clamps. As a tee: cap one port, and water does not need to flow through the tank. Tighten threaded nylon fittings about 1/2 to 1 turn past hand tight, and never exceed 6 ft-lb on the ports. The ports must seal on their internal taper, not on the threads.
  4. Check the precharge With the pump off and a faucet open, read the pressure at the valve stem with a tire gauge. Add or release air until it matches your pump’s turn-on pressure, then cap the valve tightly. Check it each season and any time it seems off, because temperature extremes and altitude can change it.

If the precharge is set above the pump’s turn-on pressure, the manual says the usable water volume shrinks. After installing, prime the pump and check for air in the lines and leaks.

How Do I Know If My Accumulator Has Failed or Is Wrongly Charged?

Most accumulator problems in Shurflo’s manual come down to a wrong air charge or a torn bladder, and Shurflo says there are no repair parts or kits. Rapid cycling points to the air charge first. Water at the air valve means the tank needs replacing.

Shurflo 182 Troubleshooting From the Manual
SymptomWhat the manual says
Pump cycles rapidlyCheck the air pressure and add or remove air
Water comes out of the air valveThe bladder is torn: replace the tank
Tank won’t hold airCheck for loose screws and the air valve; a torn bladder means replacing the tank
Leak at a fitting or portCheck the connection and confirm the port seals on its internal taper

Test with the pump off, a faucet open, and a gauge. If water is coming from the air valve, don’t keep pressurizing the tank.

If the leak is somewhere else, our guide to pump or fitting leaks will help you trace it.

Will an Accumulator Stop Pump Cycling or Water Hammer?

It can reduce pulsing and on-off cycling on a pump without an internal by-pass, and Shurflo documents a method for water hammer. But rapid cycling has other causes. For the 4008, Shurflo’s checklist points first to restrictive plumbing, filters on the main feed line, and a shut-off pressure set too low.

From the 4008 manual, check for:

  • Restrictions in the plumbing, faucets, or shower heads
  • A water filter or purifier that should be on a separate feed line instead
  • Shut-off pressure set too low

The same manual says occasional cycling with no faucets open can come from scale on the diaphragm and valves, caused by a lack of sanitizing, or from leak-back. You can sanitize the fresh water tank as part of ruling that out.

Stop and get help

  1. Don’t adjust the pump’s pressure switch or by-pass yourself. Shurflo says by-pass adjustment is for a professional technician with gauges, and a wrong setting can leave the pump unable to shut off.

For water hammer, the 182 manual says to set the precharge to the operating (dynamic) pressure where the noise happens, using a gauge in the line. Shurflo points to its Service Bulletin #1024 for more detail.

Before buying a tank, try this order:

  1. Check for leaks, including a running toilet or a leaky valve.
  2. Check the strainer and look for restrictions.
  3. Check for air in the lines.
  4. Sanitize to remove scale.
  5. Only then consider a tank, and only for a pump without an internal by-pass.

Our water pump troubleshooting guide walks through the pump side of this.

Winterizing, Sanitizing, and Safety With an Accumulator

The tank holds potable water, so include it when you sanitize and winterize. Mounting it valve stem up lets it drain and sanitize more completely, according to the 182 manual.

For winterizing, drain the system, blow it out with low-pressure air, or use potable antifreeze. Shurflo’s manual warns: never use automotive antifreeze, because death or severe injury can occur. Don’t let the tank freeze. When you de-winterize your plumbing in spring, recheck the precharge.

The hazards on this job are pressurized water and the air stored in the tank (relieve pressure first), cracked nylon ports from overtightening (6 ft-lb limit), heat near the tank, and contamination of drinking water.

Stop and get help

  1. Contact Shurflo or a qualified technician if:
  2. The pressure will not relieve.
  3. The tank leaks from the valve or will not hold air.
  4. The pump will not shut off after installation. Stop using the pump until it is sorted out.
  5. You can’t confirm your pump’s turn-on pressure, or whether your model suits an accumulator.

The 4008 manual also says to shut the pump’s power off when you leave the RV unattended. Pentair Shurflo’s number in the manual is (800) 854-3218.

Quick Recap: Diagnose First, Then Match the Precharge

Shurflo says by-pass pumps like the 4008 need no accumulator, so diagnose a cycling problem before buying anything. On a pump without a by-pass, a 182 tank with the precharge set to the pump’s turn-on pressure can smooth pulsing, though it stores only 2 to 4 oz of water. Check the precharge each season with the pump off and a faucet open.

Your next step: confirm your pump model from its label, then work through the cycling checks above before you spend money on a tank.

Frequently Asked Questions

Can I add an accumulator to a 4008 anyway?

Shurflo’s 4008 manual says a by-pass pump needs no accumulator, and Shurflo gives no precharge number for it. If you still want one, contact Shurflo first rather than guessing a precharge. If the pump will not shut off, stop using it.

How often should I check the precharge?

Check it each season, and again after de-winterizing. Temperature extremes and altitude changes can shift the pressure.

Can I put the tank on a shower or hot water line?

The manual’s temperature range tops out at 120 F, so keep it on the cold side, after the pump.

Is the 181-201 the same as the 182-200?

No. They are separate Shurflo model families with separate manuals, so match the manual to your exact model number.

Is the Shurflo 182-200 a 20 psi or 30 psi tank?

Shurflo’s 182 manual lists the 182-200 at a 30 psi factory precharge and the 182-202 at 20 psi. Some retail listings mix these up, so check the model number, and check the precharge with a gauge after install.

Written by

RV Flush Guide Editorial Team

RV Flush Guide Editorial Team creates practical, research-based guides on RV toilets, plumbing, holding tanks, sewer systems, and sanitation. We use manufacturer documentation, product manuals, and reliable technical sources to make troubleshooting and maintenance easier for RV owners.

Leave a Comment