TL;DR
- The RV water heater electric switch turns the 120-volt heating element on and off on gas/electric heaters. On Suburban heaters it is behind the outside door; on others, the location depends on the model.
- Fill the tank before you turn it on, and switch it off before you drain. Suburban warns that even brief operation without water will burn out the element.
- Gas-only heaters have no element and no electric switch.
If you’ve found a switch on your water heater, or a second one inside the RV, you may not know which one does what. The RV water heater electric switch is the on/off control for the heater’s 120-volt heating element, and on some heaters it isn’t the only switch you’ll find. This guide covers when to turn the electric heat on and off, what the switch controls, where to find it on heaters covered by the Suburban SW D-series manual and the Dometic XT manual, and what to check when electric heat won’t work. If your heater is a different brand or model, such as another Atwood, a Truma, or a custom unit, the switch location and reset steps depend on that heater’s own manual, so find it on the maker’s site or contact the maker. Gas-only heaters have no element and nothing to switch.
How Do I Turn the RV Water Heater Electric Switch On and Off?
Fill the tank first, then turn the electric switch on, and use the same switch to turn it off. Dometic says not to operate the heater without water, and Suburban warns that even brief operation of the element without water in the tank will burn it out.
The RV needs 120-volt power for the element to work, from shore power or a generator. The element draws a lot of power. Suburban’s manual rates its element at 1440 watts (12 amps) and recommends a dedicated circuit breaker for best results, and Dometic’s XT manual calls for wiring with a capacity of at least 1400 watts. Avoid running other big loads on the same circuit, and stop if the breaker trips. Hot water can scald, so test the temperature before you put your hands under it.
- Confirm the RV has 120-volt power Check that you’re plugged into shore power or running a generator and that the RV’s breaker is on.
- Fill the tank Make sure water is reaching the heater and the tank is full before you go on. If no water arrives, prime the water pump first. If you’re de-winterizing, finish refilling the system before you touch the electric switch.
- Turn the element switch on On Suburban heaters with an element, the switch is behind the outside access door, in the lower left corner of the control housing. On Dometic XT heaters, use the heater’s electric switch, and check the Dometic XT manual if you can’t find it.
- Turn it off at the same switch Before you drain the heater, switch the element off or turn off its breaker.
Dometic says an XT heater can run gas and electric at the same time for quicker recovery. Suburban’s manual doesn’t say either way, so check your own manual before you run both.
Safety
- The switch and element carry 120 volts. Turn the power off at the breaker before anyone removes a cover.
What Does the RV Water Heater Electric Switch Do?
The electric switch turns the heater’s 120-volt heating element on and off. It exists only on gas/electric models and is separate from the gas switch and the ignition reset. The element heats while the RV has 120-volt power, and a thermostat regulates the water temperature.
How to tell what you have:
- Gas-only models have no switch. If your heater has no element, there’s no electric switch to look for.
- The model number tells you a lot. In Suburban’s manual, models with an “E” (such as DE, DEL or DEM) have an electric element, and plain “D” models are gas-only. For other heaters, read the rating plate and compare it with the manual to confirm there is an element.
- The switch is not a thermostat. On Dometic XT heaters, switching electric on closes a relay that passes household-voltage power to the element, and the thermostat then controls the heating.
Where Is the Electric Switch on My Water Heater?
It depends on the heater: on Suburban heaters with an electric element, the element’s on/off switch is behind the outside door, in the lower left corner of the control housing. Some also have an interior switch plate with GAS and ELECTRIC rockers and a RESET light. On Dometic XT heaters, the electric switch location isn’t fixed. It depends on how your RV was built, so check the XT manual or your RV’s owner documents.
Switches get confused because there can be several controls in different places. The table below separates them.
| Switch or button | Where | What it does | Applies to |
|---|---|---|---|
| Element switch | Behind the outside door, lower left of the control housing | Turns the 120-volt element on and off | Suburban heaters with an element |
| Interior switch plate | Somewhere inside the RV; may look different from RV to RV | Gas-only plates have a GAS rocker; gas/electric plates also have an ELECTRIC rocker. The red RESET light comes on during the 15 second purge when the gas side starts | Suburban |
| High-limit (ECO) reset | Behind rubber grommets on the heater: “B” for the 120-volt element, “A” for the 12-volt DC side | Overheat protection. On electric it trips above 180°F; reset by pushing the grommet once the water is below 110°F | Suburban |
| Electric switch for the heater | Depends on how your RV was built; check the XT manual | Closes the relay that powers the element | Dometic XT |
To identify your heater, read the rating plate or model number and match it to a manual from the maker. Don’t pick parts or procedures from a retailer’s “fits” claim alone. The switch plate inside your RV may not match any picture, and your RV builder chose where to put it. Owners on RV forums report that some RVs add an inside switch that works the element through a relay, so the outside switch may also need to be on. That is owner-reported, not from Suburban’s manual, so check your RV’s own documentation.
Why Won’t My RV Water Heater Work on Electric?
Check the basics in order: the RV has 120-volt power, the electric switch is on, and the tank is full. Then look at the high-limit (ECO) protection. If the heater still won’t heat on electric, stop and call a qualified technician.
For no-heat or ignition problems on Atwood and Dometic units, follow our Atwood water heater troubleshooting guide by model rather than assuming every heater uses the same reset procedure.
- Is power reaching the RV? Check shore power or the generator, and make sure the breaker is on.
- Is the tank full? If water isn’t reaching the heater, see water pump not working. Don’t switch electric on until water flows.
- Is the right switch on? On Suburban, that’s the element switch, plus the ELECTRIC rocker if your plate has one. On Dometic, it’s the electric switch.
- Did the overheat protection trip? Suburban says that on electric, water above 180°F trips the manual reset, and the water must be below 110°F before you reset it by pushing the rubber grommet. Don’t press reset over and over. Our RV water heater reset button guide covers the reset steps.
- Dometic XT lockout The Dometic XT manual says a failed thermostat can open the ECO and lock out the electric mode, and it tells you to check the thermostat’s contact with the tank. Checking the thermostat means opening the heater, where 120-volt wiring is exposed. Turn the power off at the breaker first, or leave this check to a technician. After the water cools, reset the control by turning the electric switch off, then on. If the lockout comes back, contact a Dometic service center.
- Keep the gas side separate A Suburban interior plate may show a RESET light. Check your manual for what it means before you treat it as an electric fault.
A heater that won’t heat doesn’t prove the switch is bad. Don’t bypass a switch or the ECO to get heat.
Stop and get help
- Stop if the ECO keeps tripping, a lockout won’t clear, you smell burning or see scorched wiring, the breaker trips, or any cover needs to come off. A qualified technician should handle those.
When Should I Turn the Electric Switch Off?
Turn it off before you drain the heater, before any service, and whenever the tank is empty. Switch the element off at these moments:
If you are preparing the RV for freezing weather, see how to bypass the RV water heater after turning off its power and gas. The valve procedure depends on your RV’s plumbing layout.
- Before draining, Suburban’s manual says to turn off electric power at the element switch or breaker, shut off the gas, and turn off the pump. The drain an RV water heater page has the full procedure. Dometic also says to let the water cool before you drain.
- For winter storage or a bypassed heater: if the RV has a bypass kit, close it off and drain the heater completely. Don’t leave the element on with an empty tank.
- After draining, refill the tank before you switch electric back on.
- Before anyone works on the heater, turn its power off at the breaker and have a technician do the work.
Scalding and electrical hazards both apply here. Let the water cool, and use the breaker for any work near the element.
Can I Replace the Electric Switch Myself?
Identify the exact heater model first, and don’t assume a switch from another brand or model will fit. Have a qualified technician do the repair, and turn the power off at the breaker before any cover comes off. If your heater isn’t a Suburban SW D-series or a Dometic XT, use that maker’s manual.
- Read the rating plate and match the model number to the maker’s manual or parts list rather than relying on retailer “fits” lists.
- The element and switch wiring carry household voltage.
- Don’t add an aftermarket element. Dometic warns that aftermarket heating elements can lack safety controls and risk burns or an explosion, and that altering the heater voids the warranty. If you’re working on the heater because of corrosion or smell, our water heater anode rod guide covers that part.
- Treat the interior switch plate the same way: it is on a separate circuit from the element. Follow the manual or call a technician before touching it.
This guide doesn’t point to a specific replacement part, because the part has to match your heater’s exact model.
Quick Recap
Three things to remember:
- The electric switch runs only the 120-volt element. Its location depends on the model, so check your heater’s rating plate and manual.
- Water first, then electric on. Electric off before draining.
- If electric won’t heat, check power, water, the switches, and the ECO protection in that order, then call a technician.
For the next step, read how to drain an RV water heater, which starts with turning the element off. If your real problem is smell, see rotten egg smell.
Frequently Asked Questions
Can I Run Electric and Gas Together?
Dometic’s XT manual says yes. Both modes can run at once for quicker recovery. Suburban’s manual doesn’t say, so check your heater’s own manual.
Why Is There a Switch on the Heater and One Inside the RV?
On a Suburban heater with an element, the outside switch controls the element, and the interior plate may carry gas and electric rockers. On a Dometic XT, the switch location depends on how your RV was built, so check your XT manual.
What Does the Reset Button Do?
Suburban heaters have overheat (ECO) protection. On electric, it trips above 180°F, and the water must be below 110°F before you push the reset grommet. On a Dometic XT, reset the electric side by turning the electric switch off, then on, after the water cools.
Is It OK to Leave the Electric Switch on With an Empty Tank?
No. Dometic says not to operate the heater without water, and Suburban warns that even brief operation of the element without water will burn it out. Turn the switch off before you drain.
Do All RV Water Heaters Have an Electric Switch?
No. Gas-only models have no element and no electric switch. For other brands, the answer depends on the maker’s manual.